Skip to main content
. 2016 Sep 30;4(3):e28. doi: 10.2196/medinform.5909

Table 5.

Detailed performance measures of InSight when tested and trained with raw data dropouts. Operating points were chosen according to the same procedure as in Table 4.


InSight, 0 hour, 0% dropout InSight,
0 hour, 10% dropout
InSight,
0 hour, 20% dropout
InSight,
0 hour, 40% dropout
InSight,
0 hour, 60% dropout
InSight, 4 hour, 0% dropout InSight,
4 hour, 60% dropout
AUROCa 0.89 (SD 0.010) 0.87 (SD 0.006) 0.84 (SD 0.011) 0.83 (SD 0.012) 0.78 (SD 0.013) 0.75 (SD 0.008) 0.73 (SD 0.010)
APRb 0.60 (SD 0.022) 0.57 (SD 0.015) 0.54 (SD 0.022) 0.49 (SD 0.021) 0.40 (SD 0.015) 0.27 (SD 0.012) 0.27 (SD 0.009)
Sensitivity 0.80 0.80 0.80 0.80 0.80 0.80 0.80
Specificity 0.82 0.78 0.72 0.68 0.59 0.55 0.52
F1c 0.49 0.45 0.40 0.37 0.32 0.30 0.29
DORd 17.90 14.14 10.23 8.31 5.76 4.95 4.38
LR+e 4.37 3.62 2.85 2.46 1.95 1.79 1.67
LR-f 0.24 0.26 0.28 0.30 0.34 0.36 0.38
Accuracy 0.82 0.78 0.73 0.69 0.61 0.58 0.55

aAUROC: area under the receiver operating characteristic curve.

bAPR: area under the precision-recall curve.

cF1: harmonic mean of precision and recall.

dDOR: diagnostic odds ratio.

eLR+: positive likelihood ratio.

fLR-: negative likelihood ratio.