Table 3.
Segmentation results from CLASS with and without LCR, averaged over the 92 bladders in the test set.
| Segmentation Method (Test set) | Volume intersection ratio | Volume error | Absolute volume error | Average minimum distance | Jaccard index |
|---|---|---|---|---|---|
| R3D | E3D | |E3D| | AVDIST | JACCARD3D | |
| CLASS with LCR | 78.0±14.7% | 16.4±16.9% | 18.2±15.0% | 3.8±2.3 mm | 73.8±13.4% |
| CLASS without LCR | 67.3±14.3% | 29.3±15.9% | 29.4±15.6% | 4.9±2.6 mm | 65.0±13.3% |