Table 2.
Ratios of mean parameters of autofluorescent LF granules in two mdx and normal muscles in 8-week-old mice calculated from data in Table 1
Ratio of mean parameter for | Normal diaphragm/EDL | Mdx diaphragm/EDL | Mdx/normal diaphragm | Mdx/normal EDL |
---|---|---|---|---|
Granule size | 1.12 | 1.28** | 2.04**** | 1.79**** |
Feret diameter | 1.00 | 1.14** | 1.31**** | 1.15* |
Granule count or density | 1.04 | 6.96**** | 49.5**** | 7.40**** |
Granule area fraction | 1.14 | 8.98**** | 98.3**** | 12.5**** |
Significances of differences P: **** P < 0.0001; *** 0.0001 ≤ P < 0.001; ** 0.001 ≤ P < 0.01; * 0.01 ≤ P < 0.05