Kinetic parameters of surface plasmon resonance analysis with B7-2 mimetic peptides

Fig. Ligand Analyte ka, 1/ms SEM, ka % SEM, ka/ka kd, 1/s SEM, kd % SEM, kd/kd KD, μM χ2
5A pB2-4 SEB 413 10.30 2.50 9.58E−04 4.59E−05 4.80 2.32 1.05
5B pB2-6 SEB 491 8.79 1.80 1.9E−03 3.69E−05 1.94 3.90 1.07
S4A pB2-4 TSST-1 4,080 159.00 3.90 2.77E−03 8.00E−05 2.89 9.80 0.24
S4B pB2-6 TSST-1 2,530 95.40 3.77 3.04E−03 5.92E−05 1.95 1.20 0.20
S4C pB2-4 SMEZ 3,020 85.00 2.81 2.93E−03 9.32E−05 3.18 7.30 0.40
S4D pB2-6 SMEZ 1,590 50.60 3.18 2.86E−03 1.34E−04 4.69 1.79 0.12

Purified recombinant superantigens were used. Concentrations of SEB ranged from 0.78 μM in six twofold increments; concentrations of TSST-1 ranged from 0.0625 μM in five twofold increments; and concentrations of SMEZ ranged from 0.0625 μM in four twofold increments. ka, association rate; kd, dissociation rate. BIAevaluation 3.1 software (BIAcore) was used to determine KD in the linear ligand concentration range (1:1 Langmuir binding). Criteria for KD determination for complexes were SE as percent of ka and kd; χ2 values well below 2 show the quality of fit between calculated and observed binding values and attest to the purity of the ligands examined. Fitting residuals were within the range of ±2, validating the goodness of fit.