Skip to main content
. 2015 Nov 26;76(5):1478–1485. doi: 10.1002/mrm.26058

Table 1.

Mean Root Square Error (MRSE)a

Motion case Correction method
Rigid body Rigid body with sensitivity correction
First identical position case 1.94 ± 0.48%
Second identical position case 7.54 ± 1.39% 7.31 ± 1.41%
First inter‐scan motion case 14.79 ± 5.33% 6.10 ± 1.78%
Second inter‐scan motion case 17.45 ± 9.73% 6.18 ± 0.76%
a

MRSE was measured against R11, the R1RB map of the first identical‐position case for all estimations of R1 using both correction methods (mean±SD across the group). MRSE for rigid body corrected interscan motion cases was twice the scan‐rescan variability (defined as the MRSE of the second identical motion case). Additional receive sensitivity correction reduced MRSE below the level of scanrescan variability.