Skip to main content
. 2016 Oct 27;11(10):e0165419. doi: 10.1371/journal.pone.0165419

Table 3. Single exponential fit using model F(t) = C1*exp(-x*k1) + y0 for each decay curve of EGF at a power slit size of 0.5 mm and 0.8 mm (corresponding to 0.30 μW and 1.67 μW, respectively) and double exponential fit using model F(t) = y0+C1*exp(-k1*x)+C2*exp(-k2*x) for each decay curve of EGF at a power slit size of 1.2 mm and 2.0 mm (corresponding to 2.34 μW and 4.40 μW, respectively) (see Fig 4A).

For slit 0.1 mm (0.12 μW), a linear model was selected. Fit parameters are displayed in this table. R2 stands for Adjusted R- Square.

Slit(mm) Decay Parameters Statistic
y0 C1 C2 k1 k2 R2
0.1 1.8 E+4±1.1E+1 -0.16±2.7E-3 - - - 0.921
0.5 5.7E+4±1.2E+2 6.2E+4±1.0E+2 - 3.0E+4±1.5E+1 - 0.999
0.8 7.7E+4±2.0E+2 1.2E+5±2.4E+2 - 2.2E+3±1.3E+1 - 0.999
1.2 5.8E+4±1.1E+4 9.0E+4±5.6E+3 1.2E+5±5.5E+3 7.9E+3±2.1E+3 1.2E+3±3.7E+1 0.999
2.0 9.8E+4±1.8E+3 2.2E+5±1.3E+3 1.2E+5±6.4E+2 6.8E+2±4.9 5.1E+3±2.1E+2 0.999