Table 1.

Total free energies of Zn2+ binding (ΔGZn) were determined by competitive titration with Fura-2. Reported errors correspond to fitting error from a single measurement. Apparent Zn-binding enthalpies (ΔHITC) were determined by isothermal titration calorimetry. Reported errors are standard deviations among at least three replicate measurements. Apparent Zn-binding entropies (ΔSITC) were derived from the measured ΔGZn and ΔHITC values.

R14 Variant Total ΔGZn (kJ/mol) Total ΔHITC (kJ mol-1) Total ΔSITC (kJ K-1 mol-1)
c96R14 —186 ± 2 a 62 ± 13 0.84 ± 0.05
c81/c96R14 —183 ± 1 b 59 ± 1 0.82 ± 0.01
c38/c81/c96R14 —164 ± 1 10 ± 0.3 0.59 ± 0.01
a

From Ref 24.

b

From Ref 25.