Typical values for commercially available radar sensors for distance measurements and ranging taken from representative product manuals (see the citations).

Principle Frequency Typical Measurement Range Precision Measurement Value Update Rate Citation
Pulse 25 GHz 0.21 m to 13 m 10 mm (1) 0.5 Hz [83]
FMCW 24 GHz to 26 GHz 0.2 m to 80 m ±3 mm 10 Hz (2) [84]
six-port 24 GHz 0.01 m to 2.0 m (3) ±40 µm 20 Hz (4) [85]

(1) No precision stated in the manual; the given value is the maximum measurement error; (2) No measurement value update rate stated; frequency results from the serial interface; (3) Only evaluated up to 2 m due to distance limitations in laboratory; (4) Limited by the utilized serial data interface.