Skip to main content
. 2016 Sep 25;16(10):1584. doi: 10.3390/s16101584

Table 5.

The implementation time (s) for the ESMD-NLM, NLM, VMD and EEMD methods operating on the three groups of clinical ECG signals.

The Clinical ECG Signals ESMD-NLM NLM VMD EEMD
The first group
(100m.dat)
65.586 11.17 21.405 407.167
The second group
(sel100m.dat)
56.31 10.334 15.361 1107.875
The third group
(13420_12m.dat)
54.346 11.591 17.36 764.325