Skip to main content
. 2016 Oct 14;16(10):1703. doi: 10.3390/s16101703

Table 6.

The contrast logging results of EMF No. 2 in the Y-** well.

Test Depth (m) Perforated Zone Turbine Flowmeter No. 2 EMF
First (m3/d) Second (m3/d) Third (m3/d) First (m3/d) Second (m3/d) Third (m3/d)
1030.3 Y1 0 0 0 37.0 37.3 37.8
1036.7 Y2 0 0 0 15.7 15.5 15.1
1045.2 Y3 0 0 0 10.8 10.4 10.6
1055.0 Y4 0 0 0 7.4 7.1 7.8
1139.9 bore-hole bottom 0 0 0 0 0 0