Skip to main content
. 2015 Aug 3;16(4):045004. doi: 10.1088/1468-6996/16/4/045004

Figure 2.

Figure 2.

(a) The activation process was performed by applying repeated cycles of ±9 V, 5 Hz sine wave bias (sampling frequency = 10 kHz) at room temperature. (b) After activation, the devices exhibited hysteretic I–V behavior with two distinct states: LRS-1 with a resistance near 200 Ω and LRS-2 at roughly 310 Ω. (c) Stability of the two distinct LRS over repeated voltage cycling after the device was fully operational.