Table 1.
Restricted parameters | Outer | Rise-time | I | |||
---|---|---|---|---|---|---|
30 mm | 100 μs | 2 A | ||||
Chosen parameters | Inner Ø | Height | No. Turns | Copper Wire Ø | L | R |
10 mm | 3.5 mm | 119 | 0.40 mm | 224 μH | 11.6 Ω |
Ø = diameter, I = electronic circuit current, L = inductance, R = Resistance.