Skip to main content
. 2016 Jul 12;28(4):170–175. doi: 10.1016/j.joco.2016.06.005

Table 3.

Angle, anterior chamber, and lens parameters of subtypes of angle closure and normal control eyes measured by anterior segment optical coherence tomography or A-scan ultrasound.

Parameters Fellow eye PACG PACS p-value
AOD750 (mm) 0.074 ± 0.043 0.113 ± 0.083 0.146 ± 0.088 <0.001
TISA750 (mm2) 0.036 ± 0.022 0.047 ± 0.038 0.082 ± 0.040 <0.001
ACA (degree) 3.19 ± 2.73 5.00 ± 4.81 8.96 ± 5.08 <0.001
Lens thickness (mm) 4.96 ± 0.32 4.86 ± 0.40 4.92 ± 0.30 0.48
ACD (mm) 2.36 ± 0.21 2.49 ± 0.25 2.53 ± 0.28 0.01
Axial length (mm) 21.69 ± 1.13 22.48 ± 0.82 21.97 ± 0.73 0.001
Lens vault (μm) 977.00 ± 192.32 851.28 ± 186.65 890.25 ± 221.30 0.02
I-Curve (mm) 0.29 ± 0.09 0.22 ± 0.11 0.27 ± 0.08 0.01
IT750(mm) 0.47 ± 0.09 0.44 ± 0.08 0.46 ± 0.12 0.45

PACG: primary angle closure glaucoma; PACS: primary angle closure suspect; AOD750: average of nasal and temporal angle opening distance at 750 μm from scleral spur; TISA750: average of nasal and temporal trabeculo-iris space area at 750 μm from scleral spur; ACA: average of nasal and temporal anterior chamber angle; ACD = anterior chamber depth; I-curve: average of nasal and temporal iris curvature; IT750: average of nasal and temporal iris thickness at 750 μm from scleral spur. Significant P values are demonstrated in bold.