ACh EC50 values for wild-type and mutant human α3β2 and α3β4 nAChRs

EC50 values (μm) with 95% CI. The Hill slope (nH) was obtained from concentration–response curves for ACh at wild-type and mutant human α3β2 and α3β4 nAChR subtypes. ACh concentrations from 0.01 μm to 10 mm (the highest applicable concentration) were tested. All data represent mean of n = 4–8 experiments.

nAChR/mutant EC50 95% CI nH
μm
hα3β2 15.6 10.9–22.2 0.7
hα3β4 287.6 274.1–301.8 2.3
hα3β2[T59K] 14.3 12.5–16.5 1.0
hα3β4[K59T] 29.8 27.9–31.9 1.1
hα3β2[S113R] 6.0 5.0–7.2 0.9
hα3β4[R113S] 42.9 36.4–50.5 1.1
hα3β4[S114Y] 65.1 56.3–75.3 1.1
hα3β4[N115D] 140.8 123.8–160.0 1.0
hα3β4[M163K+T164S] 63.1 58.6–67.9 1.0
hα3β4[P165E] 43.9 38.6–50.0 1.2
hα3β4[T166V+M169L] 17.5 15.8–19.4 1.1