Skip to main content
. 2016 Nov 8;11(11):e0164778. doi: 10.1371/journal.pone.0164778

Table 1. Echocardiographic functional analysis for WT and MFS mice.

Parameter (units) 6 month group 12 month group
WT MFS p WT MFS p
Body weight (g) 39.1 ± 1.0 37.6 ± 1.1 0.88 41.9 ± 1.3 37.2 ± 2.2 0.14
Heart Rate (bpm) 434 ± 21 432 ± 10 0.99 453 ± 10 462 ± 18 0.97
ESV (N) (μl/g) 0.76 ± 0.08 0.81 ± 0.08 0.98 0.78 ± 0.07 0.62 ± 0.11 0.41
EDV (N) (μl/g) 1.96 ± 0.09 2.37 ± 0.14 0.13 1.97 ± 0.09 1.90 ± 0.17 0.98
SV (N) (μl/g) 1.20 ± 0.05 1.56 ± 0.09 0.04* 1.20 ± 0.07 1.29 ± 0.13 0.88
EF (%) 62 ± 3 66 ± 2 0.75 61 ± 2 68 ± 3 0.33
FS (%) 33 ± 2 36 ± 1 0.74 32 ± 1 38 ± 2 0.29
CO (N) (ml/min/g) 0.52 ± 0.03 0.68 ± 0.05 0.09 0.54 ± 0.03 0.60 ± 0.06 0.81

All parameter measurements are presented as Means ± SEM (n = 8 mice).

* indicates p < 0.05.

N, normalized with body weight. ESV End systolic volume; EDV End diastolic volume; SV Stroke volume; EF Ejection fraction; FS Fractional shortening; CO cardiac output.