Aerodynamic and acoustic measures with the subglottal pressure P0 (kPa), the volume flow rate of air, Q (cm3/s), the fundamental frequency of vibration (Hz), the acoustic intensity (dB), and the ratio between the vibration amplitude and the vocal fold length, dmax/L

Sample P0 Q Frequency Intensity dmax/L
1 1.05 33 564–618 59.22–62.6 0.088
2 0.78 40 553–563 56.7–58.6 0.081
3 0.72 40 419–432 56.1–57.9 0.098
4 1.00 40 613–683 63.2–65.9 0.076
5 0.98 50 539–728 64.8–68.5 0.081