Skip to main content
. 2016 Nov 4;10:2231–2236. doi: 10.2147/OPTH.S118503

Table 2.

Univariate linear mixed regression model results for the association of temperature with visual acuity

Outcome LASIK
LASEK
Estimate (per 1°F increase in temperature) 95% CI
P-value Estimate (per 1°F increase in temperature) 95% CI
P-value
Lower Upper Lower Upper
logMAR UDVA
POD1 −0.0039 −0.0106 0.0028 0.255 −0.0083 −0.0318 0.0152 0.484
POW1 0.0014 −0.0042 0.0070 0.612 −0.0039 −0.0203 0.0125 0.634
POM1 −0.0005 −0.0070 0.0059 0.873 0.0013 −0.0118 0.0144 0.842
POM3 −0.0005 −0.0086 0.0075 0.895 0.0086 −0.0084 0.0255 0.314
POM6 −0.0014 −0.0165 0.0138 0.858 0.0067 −0.0084 0.0218 0.372
POY1 −0.0009 −0.0116 0.0098 0.868 0.0040 −0.0087 0.0167 0.512
logMAR CDVA
POD1 −0.0065 −0.0163 0.0032 0.185 −0.0274 −0.0433 −0.0116 0.001
POW1 −0.0019 −0.0082 0.0044 0.554 −0.0099 −0.0331 0.0132 0.389
POM1 −0.0030 −0.0094 0.0033 0.345 −0.0102 −0.0210 0.0007 0.065
POM3 −0.0033 −0.0104 0.0037 0.350 −0.0048 −0.0200 0.0104 0.515
POM6 −0.0001 −0.0085 0.0084 0.987 Not enough data for model to run
POY1 0.0006 −0.0188 0.0201 0.946 Not enough data for model to run

Note: The value shown in bold reflects a P-value that is significant (P<0.05).

Abbreviations: CDVA, corrected distance visual acuity; CI, confidence interval; LASEK, laser-assisted keratomileusis; LASIK, laser in situ keratomileusis; POD1, postoperative day 1; POW1, postoperative week 1; POM1, postoperative month 1; POM3, postoperative month 3; POM6, postoperative month 6; POY1, postoperative year 1; UDVA, uncorrected distance visual acuity.