Table 6.
Diagnostic Performance of Echo-Based Wall Motion for LV Thrombus
| Sensitivity | Specificity | Accuracy | Positive Predictive Value | Negative Predictive Value | |
|---|---|---|---|---|---|
|
| |||||
| Non-Contrast Echo* | 100% (17/17) |
61% (112/184) |
64% (129/201) |
19% (17/89) | 100% (112/112) |
| Contrast Echo† | 100% (14/14) |
68% (120/176) |
71% (134/190) |
20% (14/70) | 100% (120/120) |
calculated using an apical wall motion score cutoff of ≥ 5
calculated using an apical wall motion score cutoff of ≥ 7