Skip to main content
. Author manuscript; available in PMC: 2017 Aug 7.
Published in final edited form as: Phys Med Biol. 2016 Jul 6;61(15):5486–5507. doi: 10.1088/0031-9155/61/15/5486

Figure 6.

Figure 6

Synthetic PWI data with a very high level of temporally correlated Gaussian noise (200% of mean, correlated at a scale of 20 temporal measurements). Panel A shows that the PWIP compliance distribution is reasonably close to what was specified in the simulation, and panel B shows that the correct inlet boundary condition was also recovered. Panel C shows the reduction in the error metric (Φ), as well as the recovered values of KR and the outlet BC, R. Panels D and E compare the simulated measured wall displacement data, um with the final model predictions from the PWIP, u(θ) (colormap in units ofμm), and panel F shows the relative error between the spatiotemporal maps of panels D and E.