Skip to main content
. Author manuscript; available in PMC: 2016 Nov 17.
Published in final edited form as: Int J Radiat Oncol Biol Phys. 2008 Nov 15;72(4):967–971. doi: 10.1016/j.ijrobp.2008.08.001

Table 1.

Critical organ dose-volume limits for central and superior non–small-cell lung cancer lesions using stereotactic body radiation therapy to deliver 50 Gy in four fractions

Organ Volume, cc Total dose (dose per fraction), Gy
Esophagus ≤ 1 35 (8.8)
≤ 10 30 (7.5)
Brachial plexus* Any point <40
≤ 1 35 (8.8)
≤ 10 30 (7.5)
Trachea ≤ 1 35 (8.8)
≤ 10 30 (7.5)
Main bronchus and bronchial tree ≤ 1 40 (10)
≤ 10 35 (8.8)
Heart ≤ 1 40 (10)
≤ 10 35 (8.8)
Whole lung (right & left, excluding gross tumor volume) V20 <20%
V10 <30%
V5 <40%
Major vessels ≤ 1 40 (10)
≤ 10 35 (8.8)
Skin (to 5 mm) ≤ 1 40 (10)
≤ 10 35 (8.8)
Spinal cord ≤ 1 20 (5)
≤ 10 15 (3.8)
*

Added after a case of neuropathy, as shown in Figure 3.