Table 1.
a) Detected number of voxels on magnitude, processed phase and SWI images of the in vitro iron-chitosan microsphere (μsphere) phantom and b) measured susceptibility (in ppb) from in vitro phantom data acquired at 3T are compared with the predictions shown in Figures 2, 5 and 6. The SNR of magnitude images were 12:1, 11:1 and 10:1 for TEs: 7ms, 14ms and 20ms, respectively.
At TE = 20ms, SNR = 10:1 | Diameter = 2 | Diameter = 1 | Diameter = 0.5 | |||||
---|---|---|---|---|---|---|---|---|
Number of voxels predicted | In vitro 0.5mm3 (1000μm μsphere) | Number of voxels predicted | In vitro 0.5mm3 (400μm μspheres) | In vitro 1mm3 (1000μm μsphere) | Number of voxels predicted | In vitro 0.5mm3 (200μm μspheres) | In vitro 1mm3 (400μm μspheres) | |
|
||||||||
Magnitude | 15 | 20 | 2 | 7 | 3 | 0 | 0 | 0 |
Phase | 65 | 58 | 10 | 8 | 9 | 1 | 1 | 1 |
SWI | 46 | 46 | 27 | 17 | 21 | 23 | 10 | 2 |
a) |
TE (in ms) | Diameter = 2 | Diameter = 1 | Diameter = 0.5 | |||||
---|---|---|---|---|---|---|---|---|
Δχ from simulation | In vitro 0.5mm3 (1000μm μsphere) | Δχ from simulation | In vitro 0.5mm3 (400μm μspheres) | In vitro 1mm3 (1000μm μsphere) | Δχ from simulation | In vitro 0.5mm3 (200μm μspheres) | In vitro 1mm3 (400μm μspheres) | |
|
||||||||
7 | 658 | 667 | 322 | 300 | 311 | 15 | 18 | 24 |
14 | 436 | 580 | 280 | 287 | 285 | 11 | 22 | 30 |
20 | 417 | 406 | 283 | 266 | 190 | 8 | 9 | 16 |
b) |