Skip to main content
. 2015 Oct 5;1(1):e000032. doi: 10.1136/bmjsem-2015-000032

Table 3.

Predicted postoperative (ppo) values and actually measured values 4–6 weeks after surgery for pulmonary function (n=63) and peak oxygen uptake (n=59), with limits of agreement and linear correlation (r2)

Ppo value Actually measured after surgery Difference ppo-measured p Value Limits of agreement Linear correlation
FEV1, % of predicted 69.5±19.9 72.9±17.5 −3.4±−13.7 0.06 −23.5 to 30.2 0.55
DLCO, % of predicted 63.6±18.9 65.4±18.1 −1.7±−12.3 0.27 −22.3 to 25.8 0.61
V̇O2peak, % of predicted 63.1±16.5 65.4±16.9 −2.3±−13.3 0.20 −23.8 to 28.3 0.46
V̇O2peak, mL/kg/min 18.6±5.4 19.2±5.5 −0.6±−4.1 0.24 −7.4 to 8.7 0.50

Data are presented as mean±SD.

DLCO, carbon monoxide lung diffusion capacity; FEV1, forced expiratory volume after 1 s; V̇O2peak, peak oxygen uptake.