Skip to main content
. 2016 Jun 10;31(12):2327–2335. doi: 10.1007/s00467-016-3431-4

Table 2.

Correlation of fluid parameters with proportional increase in weight from the prescribed target weight

Parameter Correlation with fluid overload by weight p value
B-lines on lung ultrasound images 0.57 0.005
Clinical examination score 0.19 0.4
Systolic blood pressure elevation above 50th centile 0.19 0.4
Bioimpedance spectroscopy 0.43 0.2
IVC diameter during inspiration 0.08 0.7
IVC diameter during expiration −0.14 0.5
Mean IVC diameter −0.05 0.8
IVC collapsibility index −0.24 0.3

IVC, Inferior vena cava