Skip to main content
. 2016 Nov 22;16:63. doi: 10.1186/s12880-016-0166-4

Table 3.

Correlations between the CAG and OCT data at single time points

CAG data OCT data Correlation p-value
Baseline
 Minimal lumen diameter, mm Fibrous-cap thickness, μm −0.004 0.971
Maximum lipid arc, ° 0.062 0.545
Mean lipid arc, ° 0.071 0.494
Lipid length, mm 0.134 0.197
Lipid index 0.133 0.200
 Diameter stenosis, % Fibrous-cap thickness, μm −0.169 0.099
Maximum lipid arc, ° 0.209 0.041
Mean lipid arc, ° 0.105 0.308
Lipid length, mm 0.099 0.341
Lipid index 0.115 0.265
 Lesion length, mm Fibrous-cap thickness, μm −0.248 0.014
Maximum lipid arc, ° −0.303 0.003
Mean lipid arc, ° 0.148 0.149
Lipid length, mm 0.754 <0.001
Lipid index 0.648 <0.001
Follow-up
 Minimal lumen diameter, mm Fibrous-cap thickness, μm −0.076 0.458
Maximum lipid arc, ° 0.086 0.410
Mean lipid arc, ° 0.087 0.433
Lipid length, mm 0.104 0.334
Lipid index 0.099 0.372
 Diameter stenosis, % Fibrous-cap thickness, μm 0.018 0.870
Maximum lipid arc, ° −0.041 0.712
Mean lipid arc, ° −0.014 0.902
Lipid length, mm 0.072 0.506
Lipid index 0.065 0.561
 Lesion length, mm Fibrous-cap thickness, μm −0.112 0.300
Maximum lipid arc, ° 0.176 0.107
Mean lipid arc, ° 0.125 0.261
Lipid length, mm 0.639 <0.001
Lipid index 0.527 <0.001

Correlations between the CAG data and OCT data were analyzed by Pearson or Spearman ranks test. A p-value < 0.05 was considered statistically significant. ° arc of lipid content. ° arc of lipid content.