Skip to main content
. 2016 Sep 19;5(5):e1049–e1056. doi: 10.1016/j.eats.2016.05.012

Fig 11.

Fig 11

Viewing from the anterior lateral portal, the tibia footprint is identified and marked with an awl approximately 2 mm anterior to the posterior aspect of the anterior horn of the lateral meniscus. The tibial flip cutter guide is placed via the anterior medial portal and the flip cutter device is drilled into the knee, deployed, and a 25-mm tibial tunnel is prepared. After this is accomplished, another looped suture should be introduced through the tibial tunnel and pulled through the far medial portal.