Skip to main content
. 2016 Oct 12;89(1067):20160109. doi: 10.1259/bjr.20160109

Table 3.

Diagnostic performance of positron emission tomography/CT parameters for detecting metastasis lymph nodes

Parameters Lesion-based results (n)
Diagnostic performance (%)
p-value
TP TN FP FN Total SN SP Accuracy PPV NPV
SUVmax (≥4.6) 21 42 3 8 74 72.4 93.3 85.1 87.5 84.0  
Size (≥6.8 mm) 23 28 17 6 74 79.3 62.2 68.9 57.5 82.4 0.003a
CV (≥0.194) 22 40 5 7 74 75.9 88.9 83.8 81.5 85.1 0.508a, 0.004b

CV, coefficient of variation; FN, false negative; FP, false positive; NPV, negative predictive value; PPV, positive predictive value; SN, sensitivity; SP, specificity; SUVmax, maximum standardized uptake value; TN, true negative; TP, true positive.

a

compared with SUVmax.

b

compared with size criteria.