Skip to main content
. 2016 Nov 2;113(46):13051–13056. doi: 10.1073/pnas.1615885113

Fig. S2.

Fig. S2.

(A) A single jump in cantilever deflection corresponding to fusion of bilayers fitted with a single exponential decay to obtain the time constant of the process. (B) Time constants as obtained by exponential fits as a function of the corresponding step height for a representative selection of curves revealing no correlation. Time resolution of the cantilever deflection is limited to 0.1–0.2 ms due to hydrodynamic damping.