Skip to main content
. 2016 Dec 5;6:38509. doi: 10.1038/srep38509

Table 2. Maximum flow rates and voltages for the cone-jet margin for different liquids.

Liquid Qmax with the simple nozzle [mL/hr] Qmax with the extender cap [mL/hr] ΔV at 1 mL/hr for the simple nozzle [kV] ΔV at 1 mL/hr for the extender cap [kV]
Ethanol 2.4 65 0.5 4.9
Methanol 1.9 32 0.7 2.9
1-Propanol 2.8 70 0.6 5.5
1-Butanol 3.4 80 0.4 6.5