Skip to main content
. 2016 Dec 6;7:458. doi: 10.3389/fphar.2016.00458

Table 1.

Comparison of particle size, PDI and EE of Rho-loaded PLGA NPs prepared by varying different parameters.

Sonication time (min) Mean diameter (nm) PDI EE (% ± SD)
Influence of sonication time
3 204 ± 12 0.18 ± 0.01 17 ± 10.41
5 190 ± 12 0.19 ± 0.03 25 ± 12.01
10 184 ± 7 0.19 ± 0.01 40 ± 2.94

PVA content (% w/v) Mean diameter (nm) PDI EE (% ± SD)

Influence of PVA content
0.5 229 ± 17 0.22 ± 0.03 72 ± 4.58
1 222 ± 5 0.23 ± 0.02 65.5 ± 1.91
2.5 184 ± 7 0.19 ± 0.01 40 ± 2.94

org/aq Mean diameter (nm) PDI EE (% ± SD)

Influence of organic to aqueous phase volume
0.5:10 232 ± 12 0.24 ± 0.01 50.25 ± 1.71
1:10 184 ± 7 0.19 ± 0.01 40 ± 2.94
2:10 195 ± 7 0.23 ± 0.01 34.5 ± 2.52