Skip to main content
. 2016 Nov 22;2016:1850401. doi: 10.1155/2016/1850401

Table 2.

Maximum and minimum von Mises stresses (MPa) in cortical and trabecular bones and implants for all fabrication materials.

Fabrication material von Mises stress (MPa)
Cortical Trabecular Implant
Y-TZP Min 0.1434 0.03851 0.953
Max 16.206 2.142 113.22
Ti-6Al-4V Min 0.14238 0.03779 0.748
Max 16.945 2.038 91.23
Ti-Nb-Zr Min 0.1416 0.03716 0.638
Max 17.271 1.948 76.673