Skip to main content
. 2016 Nov 29;28(11):3054–3059. doi: 10.1589/jpts.28.3054

Table 3. Between-day intra-rater reliability for isometric shoulder strength measurement.

ICC1, 2 Bland-Altman analysis


Mean (95% CI) SEM (SEM%) MDC95 (MDC%) Mean (LOA)(N) 95% CI(N) Fixed bias Regression p value Proportional bias
Extensor
Examiner 1
Dominant 0.884 (0.615 to 0.966) 5.7 (6.8) 15.7 (18.8) 4.4 (−16.0 to 24.8) −2.2 to 11.1 No 0.322 0.307 No
Non-dominant 0.917 (0.725 to 0.976) 3.8 (5.0) 10.5 (13.9) −0.5 (−15.7 to 14.7) −5.4 to 4.4 No −0.192 0.551 No
Examiner 2
Dominant 0.772 (0.242 to 0.933) 7.1 (8.6) 19.7 (23.9) 4.7 (−20.1 to 29.5) −3.3 to 12.8 No 0.149 0.644 No
Non-dominant 0.847 (0.491 to 0.955) 5.2 (7.0) 14.5 (19.5) 5.4 (−11.6 to 22.4) −0.1 to 10.9 No −0.147 0.647 No
Internal rotator
Examiner 1
Dominant 0.944 (0.814 to 0.984) 5.6 (7.1) 15.6 (19.8) −1.2 (−24.0 to 21.6) −8.6 to 6.2 No 0.59 0.043 Yes
Non-dominant 0.953 (0.843 to 0.986) 3.8 (5.6) 10.5 (15.6) −1.3 (−16.6 to 14.0) −6.2 to 3.7 No 0.156 0.628 No
Examiner 2
Dominant 0.960 (0.868 to 0.988) 4.7 (5.8) 13.0 (16.2) 6.1 (−8.3 to 20.5) 1.5 to 10.8 Yes 0.345 0.273 No
Non-dominant 0.957 (0.858 to 0.988) 3.9 (5.7) 10.7 (15.8) 4.1 (−9.3 to 17.5) −0.2 to 8.5 No 0.228 0.477 No

ICC: intraclass correlation coefficient; CI: confidence interval; SEM: standard error of measurement; MDC95: 95% confidence interval of minimal detectable change