Skip to main content
. 2016 Nov 24;2016:6260792. doi: 10.1155/2016/6260792

Table 1.

Stability of coagulation parameters in ACD-FFPA.

TEST Time of refrigerated storage (hours)
0 24 120
FV (IU/mL) 0.971 ± 0.18 0.864 ± 0.15 (89) 0.806 ± 0.15 (83)∗∗∗
FVII (IU/mL) 1.08 ± 0.22 0.955 ± 0.19 (88) 0.904 ± 0.16 (84)∗∗∗
FVIII (IU/mL) 1.73 ± 0.46 1.07 ± 0.30 (62)∗∗∗ 0.786 ± 0.23 (45)∗∗∗
Fibrinogen (grams/L) 2.79 ± 0.50 2.76 ± 0.45 (99) 2.77 ± 0.47 (99)
PT (seconds) 13.1 ± 0.62 13.7 ± 0.53 (105)∗∗∗ 14.1 ± 0.53 (108)∗∗∗

Values are reported as the mean ± one standard deviation; p < 0.05 and ∗∗∗ p < 0.001 versus 0 hours value for each parameter. Parenthetical values are the activity or clotting time at time t as a percentage of that at time t = 0.