Skip to main content
. 2016 Sep-Oct;31(5):389–395. doi: 10.5935/1678-9741.20160078

Table 2.

Functional capacity and maximal inspiratory pressure between groups after protocol.

Variables Control Group (n=11) Intervention Group (n=7) P
6MWT (m) 337.2±37.2 358±42.4 <0.001
% pre 104.9±2 115.5±32  
MIP (cmH2O) 57.5±12 69.6±14.1 < 0.01
% pre 107±22.2 115±24.2  

Values expressed as mean ± standard deviation. Pvalue refers to the difference between the groups. % pre=considering 100% of the baseline value pre-protocol; 6MWT=6-minute walk test; MIP=maximal inspiratory pressure