Table 3.

Angiographic Results

m-SVGs Unadjusted Adjusted*



Per-Graft Angiographic End Points Yes (n = 709) No (n = 3602) OR (95% CI) P OR (95% CI) P
SVG stenosis ≥75%, % 30.5 24.1 1.29 (1.08, 1.54) 0.006 1.24 (1.03, 1.48) 0.025
SVG occlusion 27.7 21.0 1.36 (1.13, 1.64) 0.002 1.30 (1.08, 157) 0.009
Grafts with “good” target arteries—per
graft angiographic end point, n
431 2284
SVG stenosis ≥75% 29.2 20.8 1.49 (1.20, 1.87) 0.001 1.40 (1.13, 1.76) 0.006
SVG occlusion 27.0 18.0 1.64 (1.30, 2.06) <0.001 1.53 (1.21, 1.93) 0.001

Values are percentages unless otherwise indicated.

*

Adjusted for weight, duration of surgery, harvest technique, target-vessel quality, and graft quality.

m-SVG indicates saphenous vein graft with >1 distal target; OR, odds ratio; CI, confidence interval; and SVG, saphenous vein graft.