Table 4. Comparison between the thermosensitive (study group 1) and silicone plug (study group 2) as regards mean corneal sensation pre and post plug insertion along the period of follow up.

Parameters Group 1 (range) Group 2 (range) P
Baseline (pre-plug insertion)
 Corneal centre 4.02±0.75 (3.0-5.0) 4.06±0.72 (3.0-5.0) 0.16 (NS)
 ST quadrant 3.71±0.99 (2.0-6.0) 3.67±0.95 (2.0-6.0) 0.42 (NS)
 SN quadrant 2.35±0.95 (1.0-4.0) 2.44±0.94 (1.0-4.0) 0.16 (NS)
 IT quadrant 2.31±1.10 (1.0-5.0) 2.35±1.02 (1.0-5.0) 0.53 (NS)
 IN quadrant 2.13±0.86 (1.0-4.0) 2.20±0.84 (1.0-4.0) 0.18 (NS)
3mo post-insertion
 Corneal centre 4.93±0.80 (4.0-6.0) 3.58±0.78 (2.0-5.0) <0.001 (SS)
 ST quadrant 4.31±0.79 (3.0-6.0) 3.89±0.97 (2.0-6.0) <0.001 (SS)
 SN quadrant 3.28±0.84 (2.0-5.0) 2.82±0.85 (1.0-4.0) <0.001 (SS)
 IT quadrant 3.37±0.96 (1.0-5.0) 2.94±0.99 (1.0-5.0) <0.001 (SS)
 IN quadrant 3.11±1.00 (1.0-5.0) 2.79±0.89 (1.0-4.0) 0.004 (SS)
6mo post-insertion
 Corneal centre 5.40±0.65 (4.0-6.0) 5.75±0.44 (5.0-6.0) 0.11 (NS)
 ST quadrant 5.31±0.63 (4.0-6.0) 5.46±0.51 (5.0-6.0) 0.32 (NS)
 SN quadrant 5.26±0.64 (4.0-6.0) 5.37±0.65 (4.0-6.0) 0.27 (NS)
 IT quadrant 5.28±0.69 (4.0-6.0) 5.37±0.57 (4.0-6.0) 0.66 (NS)
 IN quadrant 5.31±0.72 (4.0-6.0) 5.42±0.65 (4.0-6.0) 0.40 (NS)

NS: Statistically non significant; SS: Statistically significant; ST: Superotemporal; SN: Superonasal; IT: Inferotemporal; IN: Inferonasal.

x±s, cm