Skip to main content
. 2009 Jan 7;36(2):329–338. doi: 10.1118/1.3049594

TABLE II.

Dice similarity metric computed for critical organs before and after deformable registration.

Patient No./MVCT No. Rigid alignment Deformable registration
Bladder Rectuma Prostate Bladder Rectuma Prostate
Prostate 11 0.44 0.72 0.81 0.95 0.77 0.91
Prostate 12 0.37 0.61 0.71 0.97 0.78 0.96
Prostate 21 0.76 0.62 0.30 0.96 0.81 0.87
Prostate 22 0.56 0.58 0.41 0.97 0.83 0.88
Prostate 31 0.44 0.58 0.43 0.97 0.81 0.92
Prostate 32 0.50 0.62 0.64 0.97 0.79 0.95
GYN 11 0.57 0.63 0.96 0.77
GYN 12 0.52 0.56 0.93 0.93
GYN 21 0.40 0.69 0.92 0.83
GYN 22 0.70 0.56 0.92 0.78
Average 0.52 0.62 0.55 0.95 0.81 0.92
a

For rectum, the Dice metric is computed only on the slices that rectum was contoured on MVCT images because rectum could have been contoured for different number of slices on MVCT and kVCT.