Table 3.
Survey data: attitudes and intentions (N=11)a
| Question: To what extent do you think incorporating POCUS into your practice will improve the care you provide to patients? | |||||||
| Minimally | Somewhat | Greatly | Not sure | Declined/missing | Wilcoxon signed-rank test | ||
| Pre | 7 (46.67) | 8 (53.33) | 0.026 | ||||
| Post | 2 (13.33) | 13 (86.67) | |||||
| Question: To what degree do you agree with the following statement: point of care ultrasound is a diagnostic modality that can be used by clinicians to provide more accurate and quicker diagnosis for several disease processes? | |||||||
| Strongly agree | Agree | Neutral | Disagree | Strongly disagree | Declined | Wilcoxon signed-rank test | |
| Pre | 5 (33.33) | 6 (40.00) | 0.10 | ||||
| Post | 9 (73.33) | 2 (26.67) | |||||
| Question: To what degree do you agree with the following statement: Developing skills in point of care ultrasound will help me provide better patient care. | |||||||
| Strongly agree | Agree | Neutral | Disagree | Strongly disagree | Declined | Wilcoxon signed-rank test | |
| Pre | 6(54.45) | 4 (36.36) | 1 (9.09) | 0.0464 | |||
| Post | 10 (90.90) | 1 (9.09) | |||||
| Question: How comfortable do you feel with your understanding of the capabilities and limitations of POCUS? | |||||||
| Not at all | Minimally | Moderately | Quite | Extremely | Declined/missing | Wilcoxon signed-rank test | |
| Pre | 2 (18.18) | 8 (72.72) | 1 (9.09) | 0.0032 | |||
| Post | 1 (9.09) | 6 (54.54) | 3 (27.27) | 1 (9.09) | |||
| Question: How comfortable do you feel with your understanding of the ultrasound machine and your ability to operate it within different clinical scenarios? | |||||||
| Not at all | Minimally | Moderately | Quite | Extremely | Declined/missing | Wilcoxon signed-rank test | |
| Pre | 6 (54.54) | 4 (36.36) | 1 (9.09) | 0.0031 | |||
| Post | 11 (100) | ||||||
| Question: How likely are you to integrate POCUS into your routine clinical care? | |||||||
| Not likely to use at all | Infrequently | Occasionally | Frequently | Extensively | Declined/missing | Wilcoxon signed-rank test | |
| Pre | 5 (45.45) | 6 (54.54) | 0.59 | ||||
| Post | 5 (45.45) | 4 (36.36) | 2 (18.18) | ||||
| Question: Would you recommend this course to your colleagues? | |||||||
| Definitely | Probably | Not sure | No | ||||
| Post | 13 (86.87) | 2 (13.33) | |||||
The first 3 of the 15 faculty members participating in the pilot were not asked the above-mentioned questions.