Skip to main content
. 2016 Dec 15;11(12):e0167954. doi: 10.1371/journal.pone.0167954

Table 4. The absolute channel error (IED ratio) for the innervation zone detection (MEAN±SD).

SNR (dB) -5 0 5 10 15
# IZ
1 0.01±0.05 0.01±0.03 0.00±0.03 0.01±0.03 0.01±0.02
2 0.05±0.29 0.01±0.11 0.00±0.09 0.00±0.07 0.00±0.03
3 0.02±0.31 0.02±0.14 0.00±0.09 0.01±0.10 0.02±0.11
4 0.10±0.34 0.03±0.13 0.01±0.09 0.03±0.09 0.01±0.08
5 0.03±0.15 0.02±0.11 0.02±0.11 0.01±0.08 0.01±0.12

#IZ: the number of innervation zones in each frame; the error values could be transferred to mm by multiplying IED (5 mm); The averaging was performed over 30 simulations in each category.