Table 4. The absolute channel error (IED ratio) for the innervation zone detection (MEAN±SD).
SNR (dB) | -5 | 0 | 5 | 10 | 15 |
---|---|---|---|---|---|
# IZ | |||||
1 | 0.01±0.05 | 0.01±0.03 | 0.00±0.03 | 0.01±0.03 | 0.01±0.02 |
2 | 0.05±0.29 | 0.01±0.11 | 0.00±0.09 | 0.00±0.07 | 0.00±0.03 |
3 | 0.02±0.31 | 0.02±0.14 | 0.00±0.09 | 0.01±0.10 | 0.02±0.11 |
4 | 0.10±0.34 | 0.03±0.13 | 0.01±0.09 | 0.03±0.09 | 0.01±0.08 |
5 | 0.03±0.15 | 0.02±0.11 | 0.02±0.11 | 0.01±0.08 | 0.01±0.12 |
#IZ: the number of innervation zones in each frame; the error values could be transferred to mm by multiplying IED (5 mm); The averaging was performed over 30 simulations in each category.