Table 5. The absolute and relative muscle fiber conduction velocity error in m/s, and percentage, respectively of the proposed algorithm (MEAN±SD).

SNR (dB) -5 0 5 10 15
# IZ
1 0.23±0.20 (5±5) 0.28±0.25 (7±6) 0.13±0.13 (3±3) 0.26±0.25 (6±6) 0.22±0.14 (5±3)
2 0.65±0.46 (16±11) 0.39±0.30 (11±8) 0.28±0.30 (7±8) 0.42±0.32 (10±8) 0.33±0.26 (8±7)
3 0.80±0.65 (20±17) 0.59±0.51 (14±13) 0.45±0.38 (12±10) 0.51±0.39 (13±10) 0.48±0.36 (13±9)
4 0.48±0.46 (12±12) 0.32±0.36 (8±10) 0.33±0.37 (9±10) 0.31±0.36 (8±10) 0.22±0.26 (5±6)
5 0.61±0.48 (15±13) 0.56±0.45 (15±12) 0.41±0.39 (10±10) 0.44±0.43 (11±11) 0.42±0.35 (11±9)

#IZ: the number of innervation zones in each frame; the relative errors (%) are shown in parenthesis; The averaging was performed over 30 simulations in each category.