Skip to main content
. 2016 Dec 12;7:13786. doi: 10.1038/ncomms13786

Table 2. Table of phase corrections and final measurements of η.

  +keff in 1g
±keff in 0g
Unit
Rb K Rb K
Inline graphic 646.442 647.146 −0.356 −0.356 rad
Inline graphic −646.905 −647.132 0 0 rad
Inline graphic 2.157 (49) 31.519 (735) −0.0068 (66) 0.795 (129) rad
Sum 1.694 (49) 31.532 (735) −0.363 (66) 0.439 (129) rad
Inline graphic 3.294 (18) 1.363 (26) 2.855 (72) 3.703 (81) rad
Inline graphic 0 5 −1 −1  
Inline graphic 1.597 (52) 1.246 (735) −3.065 (73) −3.020 (152) rad
  K−κRb   K−κRb    
Inline graphic −0.352 (737)   0.049 (169)   rad
η −0.5(1.1) × 10−3   0.9(3.0) × 10−4    

Phase corrections and measurements of η are given for the single-diffraction interferometer in 1g and the DSD interferometer in 0g. In both cases, TK=2 ms, TRb=2.01 ms, Inline graphic=17 μs and Inline graphic=9 μs—yielding scale factors SRb=65.97 rad s2 m−1 and SK=66.04 rad s2 m−1, and a ratio of κ=1.0011. Values of aeff for both 1g and 0g are given in Table 3. The corresponding data are shown in Fig. 3d,e.