Skip to main content
. Author manuscript; available in PMC: 2016 Dec 16.
Published in final edited form as: Am J Obstet Gynecol. 2016 Mar 18;215(3):326.e1–326.e9. doi: 10.1016/j.ajog.2016.03.023

TABLE 1.

Industry-reported textile properties of tested mesh before loading

Mesh Vendor Pore size, mm Porosity, %
Gynemesh Ethicon 2.5 62
Restorelle Coloplast 1.8 78
Alyte Vaginal Bard 2.8 75
Alyte Stem Bard 2.0 50
UltraProa Ethicon 3.8 68

For competitive comparisons, manufacturers typically report pore size and porosity with the mesh in an unloaded state. In addition, it should be noted that manufacturers report a single value for pore size, typically the largest diameter in the mesh structure, although all prolapse meshes contain a wide range of pore sizes.

a

UltraPro (aka Artisyn) measurements made after absorbable component is absorbed.