Skip to main content
. 2004 Sep;1(2):175–185. doi: 10.1093/ecam/neh034

Figure 4.

Figure 4

HPLC separation of standard authentic compounds. The peaks are:1, propolin A (500 μg/ml); 2, propolin B (500 μg/ml); 3, propolin C (500 μg/ml); 4, propolin D (500 μg/ml); 5, propolin E (500 μg/ml); and 6, propolin F (500 μg/ml). The propolins were analyzed with a reversed-phase preparative HPLC. The conditions were: column-Luna Phenomenex (C18, 250 × 4.6 mm); solvent system, methanol:water (82:18); flow rate: 1.5 ml/min; detection, UV 280 nm.