Fig 3. Probit analylsis results for the MAP RPA (black) and real-time PCR (orange) assays using STATISTICA.

Fig 3

Data sets of eight RPA and real-time PCR assay runs as showed in Fig 1 was used. The limit of detection in RPA and real-time PCR at 95% probability were 16 and one DNA molecules of the molecule plasmid DNA standard, respectively.