Skip to main content
. Author manuscript; available in PMC: 2017 Dec 1.
Published in final edited form as: J Biophotonics. 2016 Nov 22;9(11-12):1273–1299. doi: 10.1002/jbio.201600176

Table 3.

Clinical trials of photobiomodulation (PBM) in acute responses in exercises using lower limb muscles

Reference PBM parameters Mode of irradiation Muscle/exercise Main findings
[12] Cluster with 4 laser diodes 808 nm; 500 mW; 8.3 mW/cm2;
Groups: 7 J (10 min);
  3 J (5 min);
1 site of irradiation per limb
Total delivered: 7 J/3 J
Scanning
Muscular pre-conditioning
1 site of radiation on quadriceps femoris
Maximum voluntary contraction
RCT with 5 subjects (crossover study)
No effect of PBM on muscle fatigue
[30] Laser diode 830 nm;
Diode area 0.0028 cm2; 100 mW; 35.714 W/cm2;
Volleyball athletes: 4 J (40 s); 1,428.57 J/cm2
Soccer Athletes: 3 J (30 s); 1,071.43 J/cm2
5 sites of irradiation per limb
Total delivered: 20 J (volleyball athletes)/15 J (soccer athletes)
Contact
Muscular pre-conditioning
5 sites of irradiation on rectus femoris
Wingate test
RCT with 20 athletes (crossover study)
PBM decreased blood lactate 15 min post-exercise
PBM decreased CK in blood 3 min post-exercise
No effect of PBM on muscle work
[31] Laser diode 810 nm;
Diode area 0.036 cm2; 200 mW; 5.5 W/cm2;
6 J (30 s); 164.84 J/cm2;
2 sites of irradiation per limb
Total delivered: 12 J

Versus

Cluster with 69 LEDs;
LED area 0.2 cm2;
34 LEDs 660 nm; 10 mW; 50 mW/cm2;
35 LEDs 850 nm; 30 mW; 150 mW/cm2;
0.3 J LED 660 nm (30 s), 1.5 J/cm2;
0.9 J LED 850 nm (30 s), 4.5 J/cm2;
41.7 J per site of irradiation;
2 sites of irradiation per limb
Total delivered: 83.4 J
Contact
Muscular pre-conditioning
2 sites of radiation on rectus femoris
Wingate test
RCT with 8 athletes (crossover study)
PBM (LEDT) decreased CK in blood 3 min post-exercise
No effect of PBM (LLLT) on muscle peak and mean power
No effect of PBM (LEDT) on muscle peak and mean power
No effect of PBM (LLLT) in CK 3 min post-exercise
No effect of PBM (LLLT) in blood lactate post-exercise
No effect of (LEDT) in blood lactate post-exercise
[32] Cluster with 69 LEDs;
LED area 0.2 cm2;
34 LEDs 660 nm; 10 mW; 50 mW/cm2;
35 LEDs 950 nm; 15 mW; 75 mW/cm2;
0.3 J LED 660 nm (30 s), 1.5 J/cm2;
0.4 J LED 950 nm (30 s), 2.2 J/cm2;
25.9 J per site of irradiation;
4 sites of irradiation per limb
Total delivered: 103 J
Contact
Between 2° and 3° Wingate
2 sites of radiation on rectus femoris
1 site on vastus lateralis
1 site on vastus medialis
Wingate test
RCT with 18 athletes (crossover study)
No effect of PBM on muscle peak power
No effect of PBM on fatigue index
No effect of PBM in blood lactate levels
[33] Cluster with 69 LEDs;
LED area 0.2 cm2;
34 LEDs 660 nm; 10 mW; 50 mW/cm2;
35 LEDs 850 nm; 30 mW; 150 mW/cm2;
0.3 J LED 660 nm (30 s), 1.5 J/cm2;
0.9 J LED 850 nm (30 s), 4.5 J/cm2;
41.7 J per site of irradiation
5 sites of irradiation per limb
Total delivered: 208.5 J

Versus

Cryotherapy (water immersion for 5 minutes at 5 ° C)
Contact
After exercise
2 sites of irradiation on quadriceps femoris
2 sites on hamstrings
1 site on gastrocnemius
3 Wingate tests
RCT with 6 athletes (crossover study)
PBM decreased CK in blood post-exercise
PBM decreased blood lactate post-exercise
No effect of PBM on muscle peak power
No effect of PBM on mean muscle power
No effect of PBM in C-reactive protein
[34] Cluster with:
1 laser diode 905 nm;
Diode area 0.44 cm2; 1.25 mW; 2.84 mW/cm2;
4 LEDs 875 nm;
Diode area 0.9 cm2; 17.5 mW; 19.44 mW/cm2;
4 LEDs 640 nm;
Diode area 0.9 cm2; 15 mW; 16.67 mW/cm2;

39.37 J per site of irradiation: 300 s
6 sites of irradiation per limb
Total delivered: 240 J
Contact
After exercise
2 sites of irradiation on vastus medialis
2 sites on vastus laterallis
2 sites on rectus femoris
Maximum voluntary isometric contraction (isokinetic dynamometer)
RCT with 50 subjects (10 placebo; 10 cryotherapy, 10 PBM; 10 PBM + cryotherapy; 10 cryotherapy + PBM)
PBM decreased CK post-exercise from 24 h to 96 h
PBM decreased DOMS from 24 h to 96 h
PBM improved MIVC
PBM+cryotherapy reduced efficacy of PBM
Cryotherapy+PBM and cryotherapy were similar to placebo
[35] Cluster with 5 laser diodes 810 nm;
Diode area 0.029 cm2; 200 mW; 6.89 W/cm2;
6 J per diode (30 s); 206.89 J/cm2;
30 J per site of irradiation: 5 × 6 J
6 sites of irradiation per limb
Total delivered: 180 J
Contact
Muscular pre-conditioning
2 sites of irradiation on vastus medialis
2 sites on vastus laterallis
2 sites on rectus femoris
Maximum voluntary isometric contraction (isokinetic dynamometer)
RCT with 36 subjects (18 placebo; 18 LLLT)
PBM increased maximum voluntary contraction
PBM increased LDH activity 48 h post-exercise
PBM decreased blood lactate 24 h and 48 h post-exercise
PBM decreased CK in blood 24 h and 48 h post-exercise
No PBM effect in DOMS
[36] Cluster with 69 LEDs;
LED area 0.2 cm2;
34 LEDs 660 nm; 10 mW; 50 mW/cm2;
35 LEDs 850 nm; 30 mW; 150 mW/cm2;
0.3 J LED 660 nm (30 s), 1.5 J/cm2;
0.9 J LED 850 nm (30 s), 4.5 J/cm2;
41.7 J per site of irradiation (30 s)
3 sites of irradiation per limb
Total delivered: 125.1 J
Contact
Muscular pre-conditioning
1 site of radiation on rectus femoris
1 site on vastus medialis
1 site on vastus lateralis
Maximum voluntary isometric contraction (isokinetic dynamometer)
RCT with 17 subjects (crossover study)
PBM decreased the decay of the knee extensor peak torque after a fatigue exercise protocol
[37] Cluster with:
4 laser diodes 905 nm;
Diode area 0.44 cm2; 0.3125 mW; 0.71 mW/cm2;
4 LEDs 875 nm;
Diode area 0.9 cm2; 17.5 mW; 19.44 mW/cm2;
4 LEDs 640 nm;
Diode area 0.9 cm2; 15 mW; 16.66 mW/cm2;

Groups:
10 J per site of irradiation: 76 s
30 J per site of irradiation: 228 s
50 J per site of irradiation: 381 s

6 sites of irradiation per limb
Total delivered: 60 J/180 J/300 J
Contact
Muscular pre-conditioning
2 sites of irradiation on vastus medialis,
2 sites on vastus lateralis
2 sites on rectus femoris
Eccentric contractions and maximum voluntary isometric contraction (isokinetic dynamometer)
RCT with 40 subjects (10 placebo; 30 PBM)
PBM 10 J, 30 J and 50 J increased the percentage of the knee extensor peak torque immediately after and until 96 h after eccentric exercise protocol
PBM 30 J and 50 J decreased DOMS
PBM 10 J, 30 J and 50 J decreased CK in blood from 1 h to 96 h
[38] Cluster with 5 laser diodes 810 nm;
Diode area 0.036 cm2; 200 mW; 5.495 W/cm2;

2 J per diode (10 s); 54.95 J/cm2;
6 J per diode (30 s); 164.84 J/cm2;
10 J per diode (50 s); 274.73 J/cm2;

Groups:
10 J per site of irradiation: 5 × 2 J
30 J per site of irradiation: 5 × 6 J
50 J per site of irradiation: 5 × 10 J

6 sites of irradiation per limb:
Total delivered: 60 J/180 J/300 J
Contact
Muscular pre-conditioning
2 sites of irradiation on vastus medialis
2 sites on vastus laterallis
2 sites on rectus femoris
Maximum voluntary isometric contraction (isokinetic dynamometer)
RCT with 28 athletes (7 placebo; 21 LLLT)
PBM 50 J increased knee extensor peak torque immediately after and until 96 h after eccentric exercise protocol
PBM 10 J increased knee extensor peak torque after 24 h until 96 h after eccentric exercise protocol
PBM 10 J and 50 J decreased CK and IL-6 from 24 h to 96 h
PBM (10 J, 30 J and 50 J) had no effect on DOMS
PBM 30 J had any effect in all assessments
[39] Cluster with 69 LEDs;
LED area 0.2 cm2;
34 LEDs 660 nm; 10 mW; 50 mW/cm2;
35 LEDs 850 nm; 30 mW; 150 mW/cm2;

Groups:
0.3 J LED 660 nm (30 s), 1.5 J/cm2;
0.9 J LED 850 nm (30 s), 4.5 J/cm2;
41.7 J per site of irradiation (30 s)

0.6 J LED 660 nm (60 s), 3.0 J/cm2;
1.8 J LED 850 nm (60 s), 9.0 J/cm2;
83.4 J per site of irradiation (60 s);

1.2 J LED 660 nm (120 s), 6.0 J/cm2;
3.6 J LED 850 nm (120 s), 18 J/cm2;
166.8 J per site of irradiation (120 s);

6 sites of irradiation per limb
Total delivered: 250.2 J/500.4 J/1,000.8 J
Contact
Muscular pre-conditioning
2 site of radiation on rectus femoris
2 sites of irradiation on vastus medialis
2 sites of irradiation on vastus lateralis
Maximum voluntary isometric contraction and number of repetitions (isokinetic dynamometer)
RCT with 34 subjects (crossover study)
PBM (83.4 J) increased number of repetition (knee extension)
PBM (166.8 J) increased number of repetition (knee extension)
No effects of PBM (41.7 J) in number of repetition (knee extension), torque or blood lactate levels.
No effects of PBM (all doses) on blood lactate levels and torque.
[40] Laser diode 808 nm;
Diode area 0.00785 cm2; 100 mW; 12.7 W/cm2;
7 J (70 s), 892 J/cm2;
8 sites of irradiation per limb
Total delivered: 56 J
Contact
Muscular pre-conditioning
8 sites of irradiation on rectus femoris
Knee extension (extensor chair)
RCT with 24 subjects (crossover study)
PBM increased number of repetitions
No effect of PBM on surface electromyography
[41] Laser diode 780 nm
Diode area 0.2 cm2; 30 mW; 0.15 W/cm2;
0.81 J (27 s), 4 J/cm2;
29 sites of irradiation per limb
Total delivered: 23.49 J
Contact
Muscular pre-conditioning
29 sites of irradiation on tibialis anterior
Ankle dorsiflexion (isokinetic dynamometer)
Controlled trial with 12 subjects (crossover study)
PBM increased ankle dorsiflexion peak torque in strength test
No effect of PBM on surface electromyography
No effect of PBM in blood lactate
[42] Laser diode 808 nm;
Diode area 0.0028 cm2; 100 mW; 35.71 W/cm2;
4 J (40 s); 1,428.57 J/cm2;
5 sites of irradiation per limb
Total delivered: 20 J × 3 times = 60 J
Contact
Between sets of exercise
3 sites of irradiation on rectus femoris
1 site on vastus lateralis
1 site on vastus medialis
Knee extension (isokinetic dynamometer)
RCT with 7 subjects (crossover study)
PBM increased number of repetitions
PBM decreased fatigue index in surface electromyography
[43] Laser diode 808 nm;
Diode area 0.028 cm2; 100 mW; 3.57 W/cm2;
7 J (70 s), 250 J/cm2;
8 sites of irradiation per limb
Total delivered: 56 J
Contact
Muscular pre-conditioning
8 sites of irradiation on rectus femoris
Knee extension (isokinetic dynamometer)
RCT with 30 subjects (crossover study)
PBM decreased blood lactate 6 min post fatigue exercise protocol
PBM decreased muscle fatigue by surface electromyography
No effect of PBM on muscle peak torque
No effect of PBM on muscle average power
No effect of PBM on muscle total work
No effect of PBM on muscle fatigue index
[44] Cluster with 7 laser diodes 850 nm;
Diode area 0.05 cm2; 100 mW; 2 W/cm2;
2 J per diode (20 s), 40 J/cm2;
14 J per site of irradiation: 7 × 2 J
4 sites of irradiation per limb:
Total delivered: 56 J
Contact
Muscular pre-conditioning
1 site of irradiation on vastus medialis,
1 site on vastus lateralis
1 site on rectus femoris
1 site on gastrocnemius
Running on treadmill until exhaustion
RCT with 18 subjects (crossover study)
PBM increased the peak oxygen uptake
PBM increased cardiovascular efficiency
No effect of PBM on muscle fatigue in surface electromyography
[45] Laser diode 810 nm;
Diode area 0.028 cm2; 100 mW; 3.57 W/cm2;
3 J (30 s), 107.14 J/cm2;
8 sites of irradiation per limb
Total delivered: 24 J
Contact
After exercise
8 sites of irradiation on adductor muscles
200 m maximal free style swim, 30-s crossbar jump
RCT with 20 subjects (10 placebo; 10 PBM)
PBM improved moderately 30-s crossbar jump test
No effect of PBM on 200 m maximal swim
No effect of PBM on CK and LDH
No effect of PBM on IL-1β, IL-10, TNF-α
[46] Cluster with 6 laser diodes 830 nm;
Diode area 0.0028cm2; 60 mW; 21.42W/cm2
0.6 J per diode (10 s), 214.28 J/cm2
3.6 J per site of irradiation: 6 × 0.6 J
7 sites of irradiation per limb
Total delivered: 25.2 J
Contact
Muscular pre-conditioning/after exercise
7 sites of irradiation on quadriceps femoris
Knee extension
RCT with 27 subjects (9 placebo; 9 PBM pre-conditioning; 9 PBM after exercise)
PBM applied after exercise decreased blood lactate
PBM applied after exercise decreased CK in blood
No effects of PBM (pre-conditioning) in number of maximum repetitions
No effects of PBM (pre-conditioning) on time to fatigue
[47] Cluster with 5 laser diodes 810 nm;
Diode area 0.029cm2; 200 mW; 6.9 W/cm2

6 J per diode (30 s), 206.9 J/cm2
30 J per site of irradiation: 5 × 6 J
8 sites of irradiation per limb
Total delivered: 240 J
Contact
Muscular pre-conditioning/after exercise
3 sites on quadriceps femoris
2 sites on vastus medialis
3 sites on vastus lateralis
Knee extension/flexion (plyometric exercise)
RCT with 24 subjects (12 PBM pre-conditioning; 12 PBM after exercise) - placebo therapy applied on contralateral limb
PBM (pre-conditioning or after exercise) promoted smaller muscle damage
No effects of PBM (pre-conditioning or after exercise) in MVC
No effects of PBM (pre-condtioning or after exercise) on VAS
[48] Cluster with:
4 laser diodes 905 nm;
Diode area 0.44 cm2; 0.3125 mW; 0.71 mW/cm2;
4 LEDs 875 nm;
Diode area 0.9 cm2; 17.5 mW; 19.44 mW/cm2;
4 LEDs 640 nm;
Diode area 0.9 cm2; 15 mW; 16.66 mW/cm2;

30 J per site of irradiation: 228 s
17 sites of irradiation per limb
Total delivered: 510 J
Contact
Muscular pre-conditioning
3 sites of irradiation on vastus medialis,
3 sites of irradiation on vastus lateralis
3 sites of irradiation on rectus femoris
3 sites of irradiation on biceps femoris
3 sites of irradiation on semitendinosus and semimembranosus
Bangsbo Sprint Test
RCT with 12 athletes (crossover study)
PBM improved average time in the sprints
PBM decreased fatigue index
PBM promoted lower percentage of increment in blood lactate
No effects of PBM in the best time of sprint
[49] Array with 200 LEDs;
100 LEDs 850 nm arranged in 25 clusters of 4 LEDs, 130 mW, 185.74 mW/cm2;
100 LEDs 630 nm arranged in 25 clusters of 4 LEDs, 80 mW, 114.28 mW/cm2;
Groups:
105 J (20 s), total delivered 315 J
210 J (40 s), total delivered 630 J
315 J (60 s), total delivered 945 J
Placebo - 0 J (30 s)
Sites of irradiation per limb: Whole quadriceps femoris, hamstrings and triceps surae
Total delivered: 315 J/630 J/945 J
Contact
Muscular pre-conditioning
Whole quadriceps femoris, Whole hamstrings
Whole triceps surae
Before official volleyball matches
RCT with 6 athletes (crossover study)
PBM 210 J and 315 J could prevent significant increases in CK in blood 24 h after professional volleyball matches