Skip to main content
. 2016 Dec 22;11(12):e0168949. doi: 10.1371/journal.pone.0168949

Table 3. Diagnostic test characteristics of the serial mode combinations among screening tools*.

Combination among tests Sensitivity (%) Specificity (%) Youden Index (%) PPV, % (95% CI) NPV, % (95% CI) AUC, (95% CI)
MMSE + Mini-Cog 83.11 (81.34–85.32) 91.22 (79.04–93.39) 74.33 (72.13–76.39) 72.78 (70.48–75.92) 95.03 (93.83–98.74) 87.23 (85.02–89.31)
MMSE + AD8 84.46 (82.34–86.93) 88.92 (86.43–91.03) 73.38 (71.83–75.58) 68.31 (76.03–72.47) 95.29 (93.36–98.17) 86.71 (84.52–88.83)
MMSE + CDT 84.91 (82.21–86.43) 90.44 (88.72–92.13) 75.35 (73.02–78.24) 71.54 (68.93–73.38) 95.49 (93.37–97.42) 87.72 (85.62–89.83)
Mini-Cog + AD8 81.53 (79.21–83.45) 91.92 (89.03–93.28) 73.45 (71.93–75.43) 74.03 (72.34–77.04) 94.63 (92.57–96.64) 86.73 (84.51–89.04)
Mini-Cog + CDT 85.59 (82.94–87.43) 87.89 (85.39–90.30) 73.48 (71.23–75.42) 66.67 (64.93–69.06) 95.56 (93.53–97.39) 86.74 (84.62–88.83)
AD8 + CDT 82.66 (80.39–84.43) 90.69 (88.03–92.26) 73.35 (71.28–75.04) 71.54 (68.74–74.93) 94.87 (92.51–97.03) 86.71 (84.53–88.92)
MMSE + Mini-Cog + AD8 + CDT 76.58 (74.32–78.93) 94.07 (92.32–96.23) 70.65 (68.04–73.08) 78.52 (76.86–81.28) 93.42 (91.32–96.07) 85.34 (82.91–87.80)

*Positive when all tests were positive and negative otherwise.