Skip to main content
. 2010 Apr 1;2(1):37–43. doi: 10.5114/jcb.2010.13721

Table 5.

Comparison of rectum total doses computed using rICRU and D2cc for each individual patient

Total Dose (GyEQD2)
rICRU10 Rectum D2cc
Pt1 66.8 76.9
Pt2 70.9* 76.4
Pt3 72.0* 76.6
Pt4 79.7* 77.8
Pt5 72.2* 78.0
Pt6 67.4 67.6
Pt7 68.9 65.2
Pt8 62.4 63.9
Pt9 74.6* 80.2
Pt10 81.5* 80.2
Average 71.7 74.3
StDev 5.8 6.2
Min 62.4 63.9
Max 81.5 80.2
10

rICRU - ICRU defined point dose for rectum

Bold font: > 75 GyEQD2

*

Total dose computed using rICRU point dose can detect overdose if lower end of the recommended constraint (70 GyEQD2) is used.