Skip to main content
. 2016 Dec 13;16(12):2116. doi: 10.3390/s16122116

Table 1.

MSE and SNR of simulated signals.

Method Simulated Signals MSE SNR
Before de-noising 0.0463 13.4451
VMD After de-noising 0.004 24.0253
EMD After de-noising 0.0234 17.5643