Overview of rotational seismometers using indirect measurement (only the most important parameters are listed).

Parameter Unit TAPS [55] Rotaphone
3DOF [62] 6DOF [62] D [61]
Frequency range Hz 7 × 10−1–50 (1),(2) 1–100 (2) 2–60 (2) 2–80 (2)
Sampling frequency Hz 100 250 250 250
Sensitivity (3) rad/s 1 × 10−7 1.67 ×10−8 2.16 × 10−9 3.77 × 10−9
Maximum rate rad/s 1 × 10−1 1 × 10−2 2.87 × 10−1 3.17 × 10−2
Dynamic range dB 120 100 120 120
Paired sensor spacing m 0.28 0.30 0.30 0.40
Operating temperature °C −10–45 −20–40 −20–40 −40–100 (4)
Weight kg 15 4.5 9.5 15.3
Dimensions [L × W × H] mm 450 × 180 × 350 250 (5) × 10 350 × 350 × 430 445 (5) × 112
Sensors: [pcs × type] 2 × SM-3 8 × LF-24 12 × SM-6 16 × SM-6
Natural frequency Hz 4.5 1 4.5 4.5
A/D converter: type Sigma-Delta 2 × AD16021 4 × Tedia 1 × EE & S
dynamic Bit 26 21 28 24
range V ±10 ±5 ±2.5 ±1 or ±2.5
GPS receiver and antenna Stationary system Garmin GPS 18 (mobile)
Software: type Own Own Own Own
output format miniSEED RotaCal RotaCal RotaCal

(1) Modified according to recorder MK-6 by IG PAS; (2) The instrument generally operates in a high-frequency range (above the natural frequency of the sensors used); (3) Understood as an expression for the smallest signal that can be resolved ([7], p. 79); (4) Data for geophone SM-6; (5) Disc diameter.