Skip to main content
. Author manuscript; available in PMC: 2017 Mar 31.
Published in final edited form as: Expert Rev Precis Med Drug Dev. 2016 Mar 31;1(2):207–226. doi: 10.1080/23808993.2016.1164013

Table 5.

Summary of quantitative values of four GLCM based features obtained using post contrast enhanced breast MRI images for benign and malignant lesions as reported in the literature 65,66,76,85,94.

Image Metrics Benign lesion Malignant lesion
Reference Acquisition Pre-processing gray levels Dimension ASM Entropy Contrast Correlation ASM Entropy Contrast Correlation
Sinha et al76 Post contrast DCE-MRI None 16 2D 0.02 1.96 34.3 - 0.01 2.27 535.8 -
Ahmed et al66 Post contrast DCE-MRI H.Eq 16 2D - - - - 0.01 7.13 8.5 0.8
Gibbs et al65,85 Post contrast DCE-MRI H,Eq 32 2D 0.004 5.85 25.5 0.84 0.004 5.94 23.2 0.86
Chen et al63 Post contrast DCE-MRI H.Eq 32 2D 0.01 5.41 52.1 0.6 0.01 5.44 75.8 0.6
Chen et al65 Post contrast DCE-MRI H.Eq 32 3D 0.01 5.12 67.5 0.5 0.01 5.26 69.2 0.55
Karahiliou et al94 SER map None 64 2D 0.025 1.71 12.8 0.37 0.01 2.12 23.8 0.51

H.Eq =histogram equalization, SER= signal enhancement ratio and ASM = angular second moment.