Experimental plan using L-16 orthogonal array along with induced electrostatic charge and electrical field in the designed experiments.

Experiment Number Time (h) Voltage (V) Solution Substrate Electrostatic Charge (µC) Electrical Field (V/m)
1 0 0.1 CCM UTFN 3.18 × 10−7 50
2 0 1 CCM UTFN 3.18 × 10−6 500
3 0 3 PBS STFN 9.54 × 10−6 1500
4 0 6 PBS STFN 1.9 × 10−5 3000
5 2 0.1 CCM STFN 3.18 × 10−7 50
6 2 1 CCM STFN 3.18 × 10−6 500
7 2 3 PBS UTFN 9.54 × 10−6 1500
8 2 6 PBS UTFN 1.9 × 10−5 3000
9 6 0.1 PBS UTFN 3.18 × 10−7 50
10 6 1 PBS UTFN 3.18 × 10−6 500
11 6 3 CCM STFN 9.54 × 10−6 1500
12 6 6 CCM STFN 1.9 × 10−5 3000
13 24 0.1 PBS STFN 3.18 × 10−7 50
14 24 1 PBS STFN 3.18 × 10−6 500
15 24 3 CCM UTFN 9.54 × 10−6 1500
16 24 6 CCM UTFN 1.9 × 10−5 3000